DST-27620 liquid crystal volume totaler controller
Classification:
LCD Heat/Volume/Natural Gas Accumulation Series
DST-27620 series can be equipped with vortex street, orifice plate, nozzle, electromagnetic and ∨ cone and other flowmeter instruments, which have trade settlement function. They can set small flow compensation, power failure compensation and flow payment functions to solve trade settlement disputes between supply and demand. Through the upper computer software, users can write data into regular or irregular tanks by themselves, thus conveniently realizing high-precision liquid level <=> volume display control with signal disconnection compensation function, to solve the problem of flow loss caused by the failure of on-site temperature sensor and pressure sensor, it has the function of annual, monthly and daily report of cumulative flow. Power-on recording function, total power-off time and total power-off number recording function to prevent users from power-off and stealing steam.
Keywords: Isolator
- Technical parameters
- Structural outline drawing
- Ordering Guide
-
General technical parameters
Measurement input Input signal Current: 0 ~ 20mA, 0 ~ 10mA, 4 ~ 20mA, 0 ~ 10mA square, 4 ~ 20mA square
Input impedance: ≤ 100Ω
Maximum input current limit: ≤ 30mAVoltage: 0~5V, 1~5V, 0~10V (special customization), 0~5V square, 1~5V square, 0 ~ 20mV,
0 ~ 100mV input impedance: ≥ 500KΩThermal resistance: Pt100, Cu50, Cu53, Cu100, BA1, BA2 Linear resistance: 0 ~ 400Ω Thermocouples: B, S, K, E, T, J, R, N, F2, Wre3-25, Wre5-26 Output signal Analog output: 4 ~ 20mA (load resistance ≤ 480 Ω), 0 ~ 20mA (load resistance ≤ 480 Ω), 0 ~ 10mA
(load resistance ≤ 960 Ω), 1~5V (load resistance ≥ 250KΩ), 0~5V (load resistance ≥ 250KΩ),
0~10V (load resistance ≥ 4K Ω)(special customization)Feed output: DC24V ± 1, load current ≤ 50mA Communication output: RS485/RS232 communication interface, baud rate 1200 ~ 9600bps can be set, using standard MODBUS RTU
Communication protocol, the RS-485 communication distance can reach 1km; RS-232 communication distance can reach: 15 meters.Working power supply AC 100~240V (switching power supply),50-60HZ; DC 20~29V (switching power supply). Power consumption ≤ 5W Structure -Standard snap-in -

Selection Guide
① Input channel ② Specifications and dimensions ③ Alarm output (Note 1) ④ Power supply Code Input channel Code Width * Height * Depth Code Alarm limit (relay contact output) Code Voltage range 1
21 input
2-way inputA
B
C160*80*110mm (horizontal)
80*160*110mm (vertical)
96*96*110mm (mode)Default
RL1
RL2
RL3
RL4
RL5
RL6No output
1 Limit alarm
2 Limit alarm
3 Limit alarm
4 Limit alarm
5 Limit alarm
6 Limit alarmA
DAC/DC 100-240 V
(50/60Hz)
DC 12-36V⑤ Additional functions (the following functions are optional, separated by "/", and unselected functions can be omitted) Transformed output (Note 1) Communication output Feed output For instruments with records Code Output channel Code Communication interface (communication protocol) Code Feed output (output voltage) SB transfer function Extended functionality 1
2
3
41 transmission output
2-way transmission output
3-way transmission output
4-way transmission outputD1
D2RS485 communication interface (Modbus RTU)
RS232 communication interface (Modbus RTU)1P
2P1 feeder output
2 feeder outputs
As indicated by "2P(12/24)"
The first 12V, the second 24V
Feed outputCode Transfer function Code Extended functionality U USB card transfer
(U disk)SD SD Card Expansion
(Micro SD卡)Model selection example

苏公网安备32010402001819