DST-27700 LCD multi-channel controller
Classification:
LCD Multichannel Control Series
DST-27700 series LCD display controller/paperless recorder is an intelligent multi-function secondary instrument, suitable for monitoring, controlling, recording and remote transmission of various process parameters.
Keywords: Isolator
4 universal signal input, can input DC current, DC voltage, millivolt, thermal resistance, thermocouple and other signals; measurement accuracy of 0.2 FS
• With analog transmission output and relay contact output optional
• Support RS485, RS232 serial interface, using standard MODBUS RTU communication protocol
• Support RS232C printing function, with manual printing, timing printing function
• With DC24V feed output for field transmitter power distribution
• With USB data transfer function and SD card expansion function
• Optical isolation technology is adopted between input, output, power supply and communication
- Technical parameters
- Structural outline drawing
- Ordering Guide
-
General technical parameters
Measurement input Input signal Current: 0 ~ 20mA, 0 ~ 10mA, 4 ~ 20mA, 0 ~ 10mA square, 4 ~ 20mA square
Input impedance: ≤ 100Ω
Maximum input current limit: ≤ 30mAVoltage: 0~5V, 1~5V, 0~10V (special customization), 0~5V square, 1~5V square, 0 ~ 20mV,
0 ~ 100mV input impedance: ≥ 500KΩThermal resistance: Pt100, Cu50, Cu53, Cu100, BA1, BA2 Linear resistance: 0 ~ 400Ω Thermocouples: B, S, K, E, T, J, R, N, F2, Wre3-25, Wre5-26 Output signal Analog output: 4 ~ 20mA (load resistance ≤ 480 Ω), 0 ~ 20mA (load resistance ≤ 480 Ω),
0 ~ 10mA (load resistance ≤ 960 Ω), 1~5V (load resistance ≥ 250KΩ),
0~5V (load resistance ≥ 250KΩ), 0~10V (load resistance ≥ 4KΩ)(special customization)Switching output: relay control output-AC220V/2A, DC24V/2A (resistive load)
SSR Solid State Relay Drive Voltage Output-DC 12±2.5V/30mA (Capacity)
SCR SCR zero-crossing trigger pulse output-AC400V/0.5A (capacity)
Feed output: DC24V ± 1, load current ≤ 50mACommunication output: RS485/RS232 communication interface, baud rate 1200 ~ 9600bps can be set, using standard MODBUS RTU
Communication protocol, the RS-485 communication distance can reach 1km; RS-232 communication distance can reach: 15 meters.Working power supply AC 100~240V (switching power supply),50-60HZ; DC 20~29V (switching power supply). Structure -Standard snap-in -

Selection Guide
① Input channel ② Specifications and dimensions ③ Alarm output (Note 1) ④ Power supply Code Input channel Code Width * Height * Depth Code Alarm limit (relay contact output) Code Voltage range 10
20
8-way input
16 inputA
B
C160*80*110mm (horizontal)
80*160*110mm (vertical)
96*96*110mm (mode)Default
1
2No output
Unified alarm
Separately alarmA
DAC/DC 100-240 V (50/60Hz)
DC 12-36V⑤ Additional functions (the following functions are optional, separated by "/", and unselected functions can be omitted) Transformed output (Note 1) Communication output Feed output For instruments with records Code Output channel Code Communication interface (communication protocol) Code Feed output (output voltage) SB transfer function Extended functionality 1
2Unified transmission
Separately transferD1
D2
D3RS485 communication interface (Modbus RTU)
RS232 communication interface (Modbus RTU)
RS232C print interface1P
2P1 feeder output
2 feeder outputs
As indicated by "2P(12/24)"
The first 12V, the second 24V feed outputCode Transfer function Code Extended functionality U USB card transfer (U disk) SD SD card expansion (Micro SD card) Model selection example

苏公网安备32010402001819