undefined
+
  • undefined

DST-13200 digital display DC power accumulator controller

Classification:

Digital Display Electricity Accumulation Series

DST-13200 digital display DC power totaler controller adopts automatic chip packaging technology, which has strong anti-interference ability. In the product appearance and display convenient design of dual-screen LED digital display, display content is more abundant. It can be used in conjunction with various sensors and transmitters to realize the measurement and display of physical quantities such as temperature, pressure, liquid level, speed, force, etc. The output functions include: alarm control, analog transmission, 485/232 communication, etc. Compared with traditional digital display instruments, the factory default parameters are newly added, which is easier to operate and more widely applicable.

Keywords: Isolator

• Five digit LED digital display • Can directly collect AC voltage and current signals, and can measure active power reactive power, apparent power, power factor, power frequency cycle and active power reactive power, total power • Optional with analog output, communication output and cumulative pulse output • Can directly collect three-phase AC voltage, three-phase AC current signals, can measure three-phase active power, three-phase reactive power, three-phase apparent power, three-phase power factor, three-phase power frequency cycle, three-phase harmonics and various electrical energy
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • General technical parameters

    Voltage input

    Input range: 0.0~500.0V AC/input impedance: 2MΩ

    Current input

    Input range: 0.01 ~ 5A AC/input impedance:<0.1Ω

    Output signal

    Analog output: 4 ~ 20mA (load resistance ≤ 480 Ω), 0 ~ 20mA (load resistance ≤ 480 Ω)
    0 ~ 10mA (load resistance ≤ 960 Ω), 1~5V (load resistance ≥ 250KΩ)
    0~5V (load resistance ≥ 250KΩ)

    Alarm output: relay control output-AC220V/2A, DC24V/2A (resistive load)

    Communication output: RS485/RS232 communication interface, baud rate 1200 ~ 9600bps can be set,
    Using standard MODBUS RTU communication protocol, the RS-485 communication distance can reach 1km; the RS-232 communication distance can reach 150 meters.

    Cumulative pulse output: the cumulative pulse output of active energy, reactive energy and total energy can be selected, and the output is OC gate

    Terminal

    Rated current: 18A Rated voltage: 400V

    Use environment

    Ambient temperature: -10~60 ℃; relative humidity: ≤ 85% RH; avoid strong corrosive gas.

    Working power supply

    AC 100~240V (switching power supply),50-60HZ; DC 20~29V (switching power supply).

    Power consumption

    ≤ 5W

    Structure

    Standard snap-in

  • 1

    Selection Guide

    ① Specifications and dimensions

    ② Input signal ③ Transformer output I/II ④ Alarm output

    Code

    Width * Height * Depth

    Code

    Input Type

    Code

    Output Type

    Code

    Alarm limit
    A
    B
    C
    D
    E
    F
    H

     

    160*80*110 horizontal
    80*160*110 vertical type
    96*96*110
    96*48*110 horizontal
    48*96*110 vertical
    72*72*110
    48*48*110
    V1
    V2
    V3
    V4
    0-48V
    0-110V
    0-220V
    0-500V
    0
    1
    2
    3
    4
    5
    Default
    4-20mA
    1-5V
    0-10mA
    0-5V
    0-20mA
    0-10V
    is no output
    RL1
    RL2
    RL3
    RL4
    Default
    1 bit alarm
    2-bit alarm
    3-bit alarm
    4-bit alarm
    No output
    ⑤ Communication output ⑥ Feed output ⑦ Power supply

    Code

    Communication Type Code Feed output Code Voltage range

    D1
    D2
    D3
    Default

    RS485
    RS232
    RS232C
    No output
     

    1p
    2p
    Default

    1 feed
    2-way feed
    No output
    A
    D
    220V AC
    24V DC
    ⑨ Remarks

    No remarks can be omitted