DST-15500 digital manual control instrument

Classification:

Digital PID adjustment series

DST-15500 series manual operators are suitable for use as standby operators for DCS system loop adjustment control output and intelligent regulator control output, and are suitable for industrial furnaces, electric furnaces, ovens, test equipment, shoe-making machinery, injection molding machinery, packaging machinery, food machinery, printing machinery and other industries.

Keywords: Isolator

• With "upper and lower limit alarm", "deviation alarm", "LBA alarm", "flashing alarm", "manual status alarm" and other alarm functions, with LED alarm lamp indication • With 36 kinds of signal input function, can choose any input signal type; measurement accuracy of 0.2%FS • With DC24V power distribution output for field transmitter power distribution • Optical isolation technology is adopted between input, output, power supply and communication • With a variety of dimensions and styles for users to choose from Parameter setting password lock, parameter setting power-off permanent storage, with parameter recovery system original
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • General technical parameters

    Input

    Input signal

    Current

    Voltage

    Resistance

    galvanic couple

    input impedance

    ≤ 250Ω

    ≥500kΩ

     

     

    Input current maximum limit

    ≤30mA

     

     

     

    Input voltage
    Maximum limit

     

    ≤ 6V

     

     

    Output

    Current

    Voltage

    Relay

    24V power distribution or feed

    Output load capacity

    ≤ 500Ω

    ≥ 250 KΩ
    (Note: The module must be replaced when higher load capacity is required)

    AC220V/0.5A (small)
    DC24V/0.5A (small)
    AC220V/2A (large)
    DC24V/2A (large)

    ≤30mA

    Setting method

    Panel touch key number setting; parameter setting value password lock; setting value power-off and permanent storage.

    Use environment

    Ambient temperature: 0~50 ℃; relative humidity: ≤ 85% RH; avoid strong corrosive gas

    Working power supply

    AC 100~240V (switching power supply),(50-60HZ);
    DC 20~29V (switching power supply)

    Power consumption

    ≤ 5W

    Structure

    Standard snap-in

    Communication

    Using standard MODBUS communication protocol, the RS-485 communication distance can reach 1km, and the RS-232 communication distance can reach 15 meters. Note: When the instrument is equipped with communication function, the communication converter is preferably an active converter

    Remarks:
    1.15400 using standard MODBUS RTU communication protocol, communication distance up to 1km
    2.15400 series output load capacity is AC220V/2A/DC24V/2A
    3.15500 series power consumption ≤ 4W

  • 1

    Selection Guide

    ① Specifications and dimensions

    ② Enter the indexing number

    Code

    Width * Height * Depth

    Code

    scale number (measuring range)

    Code

    scale number (measuring range)

    Code

    scale number (measuring range)
    A
    B
    C
    D
    E
    F
    H
    K
    L
    M

     

    160*80*110mm (horizontal)
    80*160*110mm (vertical)
    96*96*110mm (mode)
    96*48*110mm (horizontal)
    48*96*110mm (vertical)
    72*72*110mm (mode)
    48*48*110mm (mode)
    160*80*110mm (horizontal/light column)
    80*160*110mm (vertical/light column)
    96*96*110mm (mode/light column)
    00
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    Thermocouple B(400~1800 ℃)
    Thermocouple S(0~1600 ℃)
    Thermocouple K(0~1300 ℃)
    Thermocouple E(0~1000 ℃)
    Thermocouple T(-200.0~400.0 ℃)
    Thermocouple J(0~1200 ℃)
    Thermocouple R(0~1600 ℃)
    Thermocouple N(0~1300 ℃)
    F2(700~2000 ℃)
    Thermocouple Wre3-25(0~2300 ℃)
    Thermocouple Wre5-26(0~2300 ℃)
    Thermal resistance Cu50(-50.0~150.0 ℃)
    Thermal resistance Cu53(-50.0~150.0 ℃)
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    Thermal resistance Cu100(-50.0~150.0 ℃)
    Thermal resistance Pt100(-200.0~650.0 ℃)
    Thermal resistance BA1(-200.0~600.0 ℃)
    Thermal resistance BA2(-200.0~600.0 ℃)
    Linear resistance 0~400 Ω(-1999~9999)
    Remote transmission resistance 0-350Ω (-1999~9999)
    Remote resistance 30-350Ω (-1999~9999)
    0~20mV (-1999~9999)
    0~40mV (-1999~9999)
    0~100mV (-1999~9999)
    -20~20mV (-1999~9999)
    -100~100mV (-1999~9999)
    0~20mA (-1999~9999)
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    55
    56
    Default
    0~10mA (-1999~9999)
    4~20mA (-1999~9999)
    0~5V (-1999~9999)
    1~5V (-1999~9999)
    -5~5V (-1999~9999)
    0~10V (-1999~9999)(non-switchable)
    0 ~ 10mA (-1999~9999)
    4 ~ 20mA (-1999~9999)
    0~5V (-1999~9999)
    1~5V (-1999~9999)
    Full switch
    Special specifications
    No input (second way)

    ③ Transformer output 1(OUT1)

    ④ Transformer output 2(OUT2)

    ⑤ Alarm output (relay contact output)

    ⑥ Communication output

    Code

    Output Type (Load Resistance RL)

    Code

    Output Type (Load Resistance RL)

    Code

    Alarm limit

    Code

    Communication interface (communication protocol)

    0
    1
    2
    3
    4
    5
    K1
    K3
    K4
    K6
    8

    4-20mA(RL≤ 500Ω)
    1-5V (rl≥250kΩ)
    0-10mA(RL≤ 1KΩ)
    0-5V (rl≥250kΩ)
    0-20mA(RL≤ 500Ω)
    0-10V (rl≥4kΩ)
    Relay contact output
    SCR zero-crossing trigger pulse output
    Solid state relay drive voltage output
    Three-phase SCR zero-crossing trigger pulse output
    Special specifications
    Default
    0
    1
    2
    3
    4
    5
    K1
    K3
    K4
    K6
    8
    No output
    4-20mA(RL≤ 500Ω)
    1-5V (rl≥250kΩ)
    0-10mA(RL≤ 1KΩ)
    0-5V (rl≥250kΩ)
    0-20mA(RL≤ 500Ω)
    0-10V (rl≥4kΩ)
    Relay contact output
    SCR zero-crossing trigger pulse output
    Solid state relay drive voltage output
    Three-phase SCR zero-crossing trigger pulse output
    Special specifications
    Default
    RL1
    RL2
    RL3
    RL4

     

     

     

    No output
    1 Limit alarm
    2 Limit alarm
    3 Limit alarm
    4 Limit alarm
    Default
    D1
    D2
    D3
    Y1
    Y2
    Y3

     

    No output
    RS485 communication interface (Modbus RTU)
    RS232 communication interface (Modbus RTU)
    RS232C print interface
    External event input 1 (forced manual)
    External event input 2 (customizable)
    External event input 3 (customizable)

    ⑦ Feed output

    ⑧ Power supply

    ⑨ Remarks

    Code

    Feed output (output voltage)

    Code

    Voltage range No remarks can be omitted

    Default
    1P
    2P

    No output
    1 feeder output
    2 feeder outputs
    For example, 2P(12/24) means the first route.
    12V, the second 24V feed output

    A
    D

    AC/DC 100~240V(50/60Hz) 
    DC 20~29V