undefined
+
  • undefined

DST-15200 dual-channel digital display controller

Classification:

Digital Enhanced Series

DST-15200 digital display dual-channel control instrument for on-site temperature, pressure, liquid level, speed and other signals for collection, display, control, remote transmission, communication, printing and other processing, constitute a digital acquisition system and control system, widely used in electric power, petrochemical, metallurgy, light industry, pharmaceutical, aviation and many other fields.

Keywords: Isolator

• 15100 and 15200 series are single input, dual-screen LED digital display, and with light column analog indication function (0~100%) • 15710/15720 for dual-screen LED digital display, PV display measured value, SV display the current channel number • The 15740 is four-screen LED digital display, which can detect four measurement signals at the same time, and the measurement signals of each input channel do not interfere with each other • With 36~38 kinds of signal input function, each channel can input different signal types at the same time; measurement accuracy of 0.2%FS • With DC24V feed output for field transmitter power distribution • Optical isolation technology is adopted between input, output, power supply and communication Parameter setting password lock, parameter setting power-off permanent preservation, with parameter recovery system original setting function
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • General technical parameters

    Input

    Input signal

    Current

    Voltage

    Resistance

    galvanic couple

    input impedance

    ≤ 250Ω

    ≥500kΩ

     

     

    Input current maximum limit

    ≤30mA

     

     

     

    Input voltage
    Maximum limit

     

    ≤ 6V

     

     

    Output

    Current

    Voltage

    Relay

    24V power distribution or feed

    Output load capacity

    ≤ 500Ω

    ≥250kΩ
    (Note: The module must be replaced when higher load capacity is required)

    AC220V/0.5A (small)
    DC24V/0.5A (small)
    AC220V/2A (large)
    DC24V/2A (large)

    ≤30mA

    Setting method

    Panel touch key number setting; parameter setting value password lock; setting value power-off and permanent storage.

    Use environment

    Ambient temperature: 0~50 ℃; relative humidity: ≤ 85% RH; avoid strong corrosive gas

    Working power supply

    AC 100~240V (switching power supply),(50-60HZ);
    DC 20~29V (switching power supply)

    Power consumption

    ≤ 5W

    Structure

    Standard snap-in

    Communication

    Using standard MODBUS communication protocol, the RS-485 communication distance can reach 1km, and the RS-232 communication distance can reach 15 meters. Note: When the instrument is equipped with communication function, the communication converter is preferably an active converter

    Remarks: 1. The allowable load capacity of instrument relays with external dimensions D, E and H is AC220V/0.5A and DC24V/0.5A when outputting
    2.15700,15740 series output load capacity is AC220V/2A/DC24V/2A
    3.15700,15740 series power consumption is ≤ 4W

  • 1

    Selection Guide

    ① Specifications and dimensions

    ② Enter the indexing number

    Code

    Width * Height * Depth

    Code

    scale number (measuring range)

    Code

    scale number (measuring range)

    Code

    scale number (measuring range)
    A
    B
    C
    D
    E
    F
    H
    K
    L

     

    160*80*110mm (horizontal)
    80*160*110mm (vertical)
    96*96*110mm (mode)
    96*48*110mm (horizontal)
    48*96*110mm (vertical)
    72*72*110mm (mode)
    48*48*110mm (mode)
    160*80*110mm (horizontal/light column)
    80*160*110mm (vertical/light column)
    00
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    Thermocouple B(400~1800 ℃)
    Thermocouple S(0~1600 ℃)
    Thermocouple K(0~1300 ℃)
    Thermocouple E(0~1000 ℃)
    Thermocouple T(-200.0~400.0 ℃)
    Thermocouple J(0~1200 ℃)
    Thermocouple R(0~1600 ℃)
    Thermocouple N(0~1300 ℃)
    F2(700~2000 ℃)
    Thermocouple Wre3-25(0~2300 ℃)
    Thermocouple Wre5-26(0~2300 ℃)
    Thermal resistance Cu50(-50.0~150.0 ℃)
    Thermal resistance Cu53(-50.0~150.0 ℃)
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    Thermal resistance Cu100(-50.0~150.0 ℃)
    Thermal resistance Pt100(-200.0~650.0 ℃)
    Thermal resistance BA1(-200.0~600.0 ℃)
    Thermal resistance BA2(-200.0~600.0 ℃)
    Linear resistance 0~400 Ω(-1999~9999)
    Remote transmission resistance 0-350Ω (-1999~9999)
    Remote resistance 30-350Ω (-1999~9999)
    0~20mV (-1999~9999)
    0~40mV (-1999~9999)
    0~100mV (-1999~9999)
    -20~20mV (-1999~9999)
    -100~100mV (-1999~9999)
    0~20mA (-1999~9999)
    26
    27
    28
    29
    30
    31
    32
    33
    34
    35
    38
    55
    56
    0~10mA (-1999~9999)
    4~20mA (-1999~9999)
    0~5V (-1999~9999)
    1~5V (-1999~9999)
    -5~5V (-1999~9999)
    0~10V (-1999~9999)(non-switchable)
    0 ~ 10mA (-1999~9999)
    4 ~ 20mA (-1999~9999)
    0~5V (-1999~9999)
    1~5V (-1999~9999)
    0~600V(-1999~9999)(non-switchable)
    Full switch
    Special specifications

    ③ Transformer output 1(OUT1)

    ④ Transformer output 2(OUT2)

    ⑤ Alarm output (relay contact output)

    ⑥ Communication output

    Code

    Output Type (Load Resistance RL)

    Code

    Output Type (Load Resistance RL)

    Code

    Alarm limit

    Code

    Communication interface (communication protocol)

    Default
    0
    1
    2
    3
    4
    5
    8

    No output
    4-20mA(RL≤ 500Ω)
    1-5V (rl≥250kΩ)
    0-10mA(RL≤ 1KΩ)
    0-5V (rl≥250kΩ)
    0-20mA(RL≤ 500Ω)
    0-10V (rl≥4kΩ)
    Special specifications
    Default
    0
    1
    2
    3
    4
    5
    8
    No output
    4-20mA(RL≤ 500Ω)
    1-5V (rl≥250kΩ)
    0-10mA(RL≤ 1KΩ)
    0-5V (rl≥250kΩ)
    0-20mA(RL≤ 500Ω)
    0-10V (rl≥4kΩ)
    Special specifications
    Default
    RL1
    RL2
    RL3
    RL4

     

     

     

    No output
    1 Limit alarm
    2 Limit alarm
    3 Limit alarm
    4 Limit alarm
    Default
    D1
    D2
    D3

     

    No output
    RS485 communication interface (Modbus RTU)
    RS232 communication interface (Modbus RTU)
    RS232C print interface

    ⑦ Feed output

    ⑧ Power supply

    ⑨ Remarks

    Code

    Feed output (output voltage)

    Code

    Voltage range This series can be used to add (subtract), multiply and divide the operation function, can be in the model after the note
    No remarks can be omitted

    Default
    1P
    2P

    No output
    1 feeder output
    2 feeder outputs
    For example, 2P(12/24) means the first route.
    12V, the second 24V feed output

    A
    D

    AC/DC 100~240V(50/60Hz) 
    DC 20~29V