DST-15740 four-way digital display controller
Classification:
Digital Enhanced Series
DST-15740 series of four-way measurement and display control instrument for the field temperature, pressure, liquid level, speed and other signals for collection, display, control, remote transmission, communication, printing and other processing, constitute a digital acquisition system and control system, suitable for the need for multi-point inspection system.
Keywords: Isolator
- Technical parameters
- Structural outline drawing
- Ordering Guide
-
General technical parameters
Input
Input signal
Current
Voltage
Resistance
galvanic couple
input impedance
≤ 250Ω
≥500kΩ
Input current maximum limit
≤30mA
Input voltage
Maximum limit≤ 6V
Output
Current
Voltage
Relay
24V power distribution or feed
Output load capacity
≤ 500Ω
≥250kΩ
(Note: The module must be replaced when higher load capacity is required)AC220V/0.5A (small)
DC24V/0.5A (small)
AC220V/2A (large)
DC24V/2A (large)≤30mA
Setting method
Panel touch key number setting; parameter setting value password lock; setting value power-off and permanent storage.
Use environment
Ambient temperature: 0~50 ℃; relative humidity: ≤ 85% RH; avoid strong corrosive gas
Working power supply
AC 100~240V (switching power supply),(50-60HZ);
DC 20~29V (switching power supply)Power consumption
≤ 5W
Structure
Standard snap-in
Communication
Using standard MODBUS communication protocol, the RS-485 communication distance can reach 1km, and the RS-232 communication distance can reach 15 meters. Note: When the instrument is equipped with communication function, the communication converter is preferably an active converter
Remarks: 1. The allowable load capacity of instrument relays with external dimensions D, E and H is AC220V/0.5A and DC24V/0.5A when outputting
2.15700,15740 series output load capacity is AC220V/2A/DC24V/2A
3.15700,15740 series power consumption is ≤ 4W -

Selection Guide
① Specifications and dimensions
② Enter the indexing number
Code
Width * Height * Depth Code
scale number (measuring range) Code
scale number (measuring range) Code
scale number (measuring range) A
B
C
D
E
F
H
K
L160*80*110mm (horizontal)
80*160*110mm (vertical)
96*96*110mm (mode)
96*48*110mm (horizontal)
48*96*110mm (vertical)
72*72*110mm (mode)
48*48*110mm (mode)
160*80*110mm (horizontal/light column)
80*160*110mm (vertical/light column)00
01
02
03
04
05
06
07
08
09
10
11
12Thermocouple B(400~1800 ℃)
Thermocouple S(0~1600 ℃)
Thermocouple K(0~1300 ℃)
Thermocouple E(0~1000 ℃)
Thermocouple T(-200.0~400.0 ℃)
Thermocouple J(0~1200 ℃)
Thermocouple R(0~1600 ℃)
Thermocouple N(0~1300 ℃)
F2(700~2000 ℃)
Thermocouple Wre3-25(0~2300 ℃)
Thermocouple Wre5-26(0~2300 ℃)
Thermal resistance Cu50(-50.0~150.0 ℃)
Thermal resistance Cu53(-50.0~150.0 ℃)13
14
15
16
17
18
19
20
21
22
23
24
25Thermal resistance Cu100(-50.0~150.0 ℃)
Thermal resistance Pt100(-200.0~650.0 ℃)
Thermal resistance BA1(-200.0~600.0 ℃)
Thermal resistance BA2(-200.0~600.0 ℃)
Linear resistance 0~400 Ω(-1999~9999)
Remote transmission resistance 0-350Ω (-1999~9999)
Remote resistance 30-350Ω (-1999~9999)
0~20mV (-1999~9999)
0~40mV (-1999~9999)
0~100mV (-1999~9999)
-20~20mV (-1999~9999)
-100~100mV (-1999~9999)
0~20mA (-1999~9999)26
27
28
29
30
31
32
33
34
35
38
55
560~10mA (-1999~9999)
4~20mA (-1999~9999)
0~5V (-1999~9999)
1~5V (-1999~9999)
-5~5V (-1999~9999)
0~10V (-1999~9999)(non-switchable)
0 ~ 10mA (-1999~9999)
4 ~ 20mA (-1999~9999)
0~5V (-1999~9999)
1~5V (-1999~9999)
0~600V(-1999~9999)(non-switchable)
Full switch
Special specifications③ Transformer output 1(OUT1)
④ Transformer output 2(OUT2)
⑤ Alarm output (relay contact output)
⑥ Communication output
Code
Output Type (Load Resistance RL) Code
Output Type (Load Resistance RL) Code
Alarm limit Code
Communication interface (communication protocol) Default
0
1
2
3
4
5
8No output
4-20mA (unified transmission)
1-5V (unified transmission)
0-10mA (unified transmission)
0-5V (unified transmission)
0-20mA (unified transmission)
0-10V (unified transmission)
Special specifications00
01
02
03
04
054-20mA (separately)
1-5V (respectively)
0-10mA (transmission respectively)
0-5V (respectively)
0-20mA (transmission respectively)
0-10V (respectively)Default
RLU
RLENo output
Unified alarm
Separately alarmDefault
D1
D2
D3No output
RS485 communication interface (Modbus RTU)
RS232 communication interface (Modbus RTU)
RS232C print interface⑦ Feed output
⑧ Power supply
⑨ Remarks
Code
Feed output (output voltage) Code
Voltage range This series can be used to add (subtract), multiply and divide the operation function, can be in the model after the note
No remarks can be omittedDefault
1P
2PNo output
1 feeder output
2 feeder outputs
For example, 2P(12/24) means the first route.
12V, the second 24V feed outputA
DAC/DC 100~240V(50/60Hz)
DC 20~29V
苏公网安备32010402001819