DST-815 thin temperature transmission isolator

Classification:

Thermocouple, resistance input

DST-815 thin temperature transmission isolator will be on-site thermal resistance or thermocouple signal after isolation amplification processing, converted into linear with the temperature of the DC signal output to the control system, used as a thermocouple temperature transmission, with cold junction temperature automatic compensation function. The parameters can be modified by the supporting upper computer software, which can be used with the unit combination instrument, DCS, PLC and other systems to provide field instrument signal isolation, signal conversion, signal distribution, signal processing, etc., so as to improve the anti-interference ability of the automatic control system of industrial production process and ensure the stability and reliability of the system. This product variety is divided into one in and one out, one in and two out, two in and two out, and the input and output magnetic isolation.

Keywords: Isolator

• Single channel, dual channel This series of varieties have one in and one out, one in and two out, two in and two out, four in and four out. • DC voltage, current, thermal resistance, thermocouple input • Analog output for power distribution • The signal type and test range of some products can be programmed by the supporting PC software • Input/output/power magnetic isolation Transmission accuracy (20 ℃):0.1%FS • Short response time, thin thickness, low power consumption • Plug-in terminals for easy installation and maintenance • Standard 35mm DIN rail clip-on mount
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • Technical parameters

     
    Input
    Input signal Two-or three-wire thermal resistance, thermocouple (signal type and measurement range can be programmed by the supporting upper computer software)
    Output
    Output signal 4-20mA、0-10mA、0-20mA、1-5V、0-5V
    Output load 4-20mA, 0-10mA, 0-20mA load resistance RL≤ 400 Ω;1-5V, 0-5V load resistance RL≥ 250KΩ

     

    General technical parameters

     

    Power
    Power DC20-32V
    Power consumption Single output power consumption: ≤ 1.5W; Dual output power consumption: ≤ 2.6W
    Other parameters
    Insulation resistance
    (between input/output/power)
    ≥ 100MΩ (at 500VDC)
    Insulation strength
    (between input/output/power)
    2000Vrms (1 min, no spark)
    Working temperature -10~50 ℃ (no condensation, no icing)
    Relative humidity 25%~85%RH
    save temperature -10~60 ℃ (no condensation, no icing)
    temperature drift 0.0075%FS/℃
    Installation method 35mm DIN rail mounting
    Mounting dimensions 13*108*121.2mm (width * height * depth)
    Transmission accuracy (20 ℃) 0.1%FS (0.2%FS ± 1 word for 815 temperature transmission series)
    Response time ≤ 2ms
    Weight About 130 grams
    Electromagnetic compatibility Comply with GB/T18268 industrial equipment application requirements (IEC 61326-1)
    Applicable field equipment Two-wire, three-wire transmitter, DC current source
  • Structural outline drawing

    1

     

    General Structure Outline Drawing

     

    1

  • 1

     

    For example:

    Input signal:PT100 thermal resistance, output signal: 4-20mA, one in and one out. Type selection: DST-81511-IS-14-0-D;

    Input signal:PT100 thermal resistance, output signal: 4-20mA, one in and two out. Type selection: DST-81512-IS-14-0/0-D;

    Input signal:PT100 thermal resistance, output signal: 4-20mA, two in and two out. Selection is: DST-81522-IS-14/14-0/0-D;

    Remarks:The current output and voltage output are not switchable and need to be completed by changing the hardware. Please indicate clearly when ordering.