DST-MSW-28G-RA Series
Classification:
Network Managed Industrial Ethernet Switch
The DST-MSW-28G-RA series gigabit network management rack-mounted industrial Ethernet switches meet IEC61850-3 standards and conform to the national network A- level standards. They support up to 24 100 megabit/gigabit ports and can be configured with 28 gigabit SFP modules. It has complete management functions, including QoS, VLAN, IGMP Snooping/GMRP, Port Trunking, SNMP V1/V2/V3, RSTP/STP, etc. The unique RingGo redundant ring network protocol, the network link switching and recovery time is less than 20ms, which improves the reliability of the network. Redundant power input, wide temperature design, strong anti-electromagnetic interference ability, especially suitable for extremely strict requirements such as digital substations and other applications.
Keywords: Isolator
- Technical parameters
- Structural outline drawing
- Ordering Guide
-
Switch Parameters
IEEE Standards IEEE 802.3 10BaseT Ethernet IEEE 802.3u 100BaseT(X) and 100BaseFX Fast Ethernet IEEE 802.3ab 1000BaseT(X) Ethernet IEEE 802.3z 1000BaseX Ethernet IEEE 802.3x Flow Control IEEE 802.3d Spanning Tree Protocol IEEE 802.1w Rapid Spanning Tree Protocol IEEE 802.1s Multiple Spanning Tree Protocol IEEE 802.1p Class of Service IEEE 802.1Q VLAN Tag (Virtual Local Area Network Tag) IEEE 802.3ad LACP (Link Aggregation Control Protocol) IEEE 802.1x User Authentication (user authentication) IEEE 802.1ab LLDP (Logical Link Discovery Protocol) Exchange characteristics MAC Address Table 8K/16K Packet Caching 4Mbit Processing method store and forward Switch delay time < 10us Switch Backplane Bandwidth 56Gbps/128Gbps Interface Number of RJ45 ports Up to 24 100 megabytes/gigabytes Number of light ports Up to 4 100 megabytes/gigabytes optical ports optical port transmission distance Multimode 2km, single mode 20km/40km/60km/120km optional Gigabit optical port Up to 28 Gigabit SFP slots LED indicator Power, electrical port, optical port, status Console control port RS-232,RJ45 Connector, 115200bps, 8, N, 1 Power Terminal Description 4-pin power terminal, 2-pin alarm terminal Power Parameters
Dual power supply 220VAC/DC optional;
220V power support range of 85~264VAC/77 ~ 300VDCPower consumption
Maximum 20 watts Power Protection Reverse connection protection, overload protection Alarm 3-pin terminal Environment Properties Working temperature -40~75° C Storage temperature -40~85° C Relative humidity 5 ~ 95% (no frost) Software Features MIB RFC 1215 Trap, RFC1213 MIB II,RFC 1157 SNMP MIB, RFC 1493 Bridge MIB,
RFC 2674 VLANE, RFC 1643,RFC 1757, RSTP MIB, Private MIB, LLDP MIB.Equipment Management Support SNMP v1, v2, v3
Supports Web management, Telnet, and serial CLI configuration
支持DHCP-client
Support user login password protectionSecurity Features Support ACL
Supports port-based MAC filtering
Support MAC address binding
Support for port-based 802.1X authentication
Support for RADIUS authentication
Support system self-defense to prevent attacks such as DDOSVLAN Support port VLAN, IEEE 802.1Q Tag
Maximum number of VLANs available: 64,VID range 1~4094
Support management VLANPort convergence Static LACP support
Supports 14 aggregation groups with up to 8 ports per groupnetwork redundancy 支持STP(IEEE 802.1d),RSTP(IEEE 802.1w)和 MSTP(IEEE 802.1s)
Private ring network (self-healing time <10ms)QoS Supports absolute priority and relative priority scheduling
4 priority queues
Support scheduling based on 802.1p/DSCP queues, 8 queues per portPort Mirroring Supports port-based unidirectional and bidirectional traffic mirroring IGMP Multicast Supports IGMP Snooping V1/V2, supports up to 256 multicast groups Port Bandwidth Control Support the speed limit of packet traffic to and from the port, the minimum granularity is
64Kbpsbroadcast storm suppression Support suppression of broadcast messages, multicast messages and unknown unicast messages Equipment maintenance Syslog support
支持RMON(Remote Network Monitoring)
Support for Ping detection
Support for Link Layer Discovery Protocol LLDP(Link Layer Discovery Protocol)SNTP Support SNTP protocol Firmware Upgrade Support WEB page and serial TFTP upgrade Profile Support import and export of configuration files Certification EMI FCC Part 15. CISPR(EN55022) class A EMS EN 61000-4-2(ESD)Level 4
EN 61000-4-3(RS)Level 4
EN 61000-4-4 (OJ)Level 4.
EN 61000-4-5(Surge)Level 4.
EN 61000-4-6(CS)Level 4
EN 61000-4-8Mechanical IEC60068-2-6 (vibration)
IEC60068-2-27 (impact)
IEC60068-2-32 (free fall)Environment Properties Standard Model -10~60°C Wide temperature model -40 to 85°C Storage temperature -40 to 85°C Relative humidity 5 ~ 95% (no frost) Physical characteristics Shell IP40 metal enclosure Installation method Standard rack mount Dimensions 440(W) x 44(H) x 352(D)m Warranty period MTBF 360000h Warranty Period 5 years -
Dimensional drawing

-
Configuration
Model Product Description DST-MSW-24TX/4MP-RA Network management rack type, 24 100 megabyte ports, 4 100 megabyte SFP slots, 220V dual power supply DST-MSW-24TX/4SC-RA Network management rack type, 24 100 megabyte ports, 4 100 megabyte SC ports, single mode double fiber 20km, 220V double power supply DST-MSW-24TX/4GSC-RA Gigabit network management rack type, 24 100 megabit ports, 4 gigabit SC ports, single mode double fiber 20km, 220V dual power supply DST-MSW-24TX/4GP-RA Gigabit network management rack type, 24 100 megabytes, 4 gigabit SFP slots, 220V dual power supply DST-MSW-24GT/4GSC-RA Gigabit network management rack type, 24 gigabit ports, 4 gigabit SC ports, single mode double fiber 20km, 220V dual power supply DST-MSW-24GT/4GP-RA Gigabit network management rack type, 24 gigabit power ports, 4 gigabit SFP slots, 220V dual power supply The following models are not available DST-MSW-16TX/8MP-RA Network management rack type, 16 100 M ports, 8 100 M SFP slots, 220V dual power supply DST-MSW-8TX/16MP-RA Network management rack type, 8 100 megabyte ports, 16 100 megabyte SFP slots, 220V dual power supply DST-MSW-24MP/4GP-RA Network management rack type, 24 100 M SFP slots, 4 Gigabit SFP slots, 220V dual power supply DST-MSW-16GT/12GP-RA Network management rack type, 16 gigabit ports, 12 gigabit SFP slots, 220V dual power supply DST-MSW-8GT/20GP-RA Network management rack type, 8 gigabit ports, 20 gigabit SFP slots, 220V dual power supply DST-MSW-28GP-RA Network management rack type, 28 gigabit SFP slots, 220V dual power supply Switch Naming Rules
DST
-
X1
-
X2
X3
/
X4
X5
-
X6
Detailed description of parameters
DST
Prefix
Enterprise Feature Code
X1
Switch Classification
SW: unmanaged switch; MSW: managed switch; MC: photoelectric converter
X2
Number of ports
X3
Port Identification
TX: 100 megabytes; GT: Gigabit port; GB: Gigabit COMBO;
MP: 100 Gigabit SFP slot; GP: Gigabit SFP slot; X: 10 Gigabit SFP slot;
MC: Multimode 2km 100 M SC optical port; GMC: Multimode 2km Gigabit SC optical port;
SC: single-mode double-fiber 20km 100 M SC optical port; SC40: single-mode double-fiber 40km 100 M SC optical port;
GSC: single-mode dual-fiber 20km Gigabit SC optical port; GSC40: single-mode dual-fiber 40km Gigabit SC optical port;
MT: Multimode 2km 100 M ST optical port; GMT: Multimode 2km Gigabit ST optical port;
ST: single-mode double-fiber 20km 100 M ST optical port; ST40: single-mode double-fiber 40km 100 M ST optical port;
GST: single-mode dual-fiber 20km Gigabit ST optical port; GST40: single-mode dual-fiber 40km Gigabit ST optical port;
S3: single-mode single-fiber 1310 transmission, 1510 reception; S5: single-mode single-fiber 1510 transmission, 1310 reception;X4
Number of ports
X5
Port Identification
Refer to the X3 port identification for an example
X6
Installation method
The default is rail type, R: rack type; 3R: three-layer rack type; RA: State Grid Class A standard rack type; P:POE function;
Remarks
Guide rail type default 24VDC dual power supply; Rack type and three-layer rack type default AC/DC110 ~ 220V single power supply; State Grid Class A default AC/DC110 ~ 220V dual power supply; With POE function default 48V single power supply;
Under non-default conditions: AC/DC110 ~ 220V single power supply can be selected for some models of rail-type switches, and the suffix of the model needs to be added: -220V;Switch Example