DST-662 Current Output Isolated Safety Barrier

Classification:

Current analog output

DST-662X-EX-a/b-c/d type current output operation terminal isolation barrier, the safety zone from DCS or PLC and other electrical equipment through isolation and then output linear DC voltage/current signal, in order to drive the field actuator, the product needs independent power supply, input/output/power three isolation, can be used in the field solenoid valve, two-wire valve positioner, electrical converter and other equipment. According to GB/T 3836.1-2021 and GB/T 3836.4-2021, it has passed the inspection and obtained the ccc certificate. It is suitable for installation and use in safe areas and can be used together with intrapexy safety equipment in Zone 0, Zone 1 and Zone 2 of explosive gas hazardous places.

Keywords: Isolator

• National Instrument Explosion-proof Safety Supervision and Inspection Station (CNEX) certification • Explosion-proof sign [Exia Ga] IIC According to GB3836.1, GB3836.4, GB3836.20 standard inspection, to obtain ccc certificate • Single channel, dual channel This series of varieties have one in and one out, one in and two out, two in and two out. • DC voltage, current, thermal resistance, thermocouple input • Analog output, loop-powered • The signal type and test range of some products can be programmed by the supporting PC software • Plug-in terminals for easy installation and maintenance • Standard 35mm DIN rail clip-on mount
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • Technical parameters

     

    Safety side
    Input signal Voltage/current signal input (determine when ordering or configure programming self-programming)
    input impedance Current ≤ 250 Ω, voltage ≥ 510KΩ
    Hazardous side
    Output signal Current output
    Output load RL≤ 500Ω

     

    General technical parameters 

     

    Power
    Power DC24V ±10%
    Power consumption Power consumption: ≤ 2.5W
    Other parameters
    Insulation strength
    (Between Inthenine Safety End/Non-Inthenine Safety End)
    1500Vrms (1 min, no spark)

    Working temperature
    Relative humidity

    -10~50 ℃ (no condensation, no icing)
    25%~85%RH
    save temperature -10~60 ℃ (no condensation, no icing)
    Installation method 35mm DIN rail mounting
    Mounting dimensions 17.5*111.4*121.2mm (width * height * depth)
    Transmission accuracy (20 ℃) 0.2%FS ± 1 word
    Weight About 130 grams
    Electromagnetic compatibility Comply with GB/T18268 industrial equipment application requirements (IEC 61326-1)
    Applicable field equipment Two-wire, three-wire transmitter, DC current source
  • Structural outline drawing

    结构外形图

    General Structure Exterior

     

    通用结构外型图

  •  

    1

     

    For example:

    Input signal: 0-20mA, output signal: 0-20mA, one in and one out. Type selection: DST-66211-EX-25-4;

    Input signal: 0-20mA, output signal: 0-20mA, two in and two out. Selection is: DST-66211-EX-25 -4/4;