DST-605 thermocouple input isolated safety barrier

Classification:

Thermocouple Input

DST-605X-EX-a/b-c/d type thermocouple is input to the isolation barrier at the detection end, and the thermocouple signal in the dangerous area is converted into the corresponding voltage or current signal/RS485 signal/switch signal and output to the safe area. The product requires independent power supply, input/output/power three isolation. This product can be used with a variety of thermocouple sensors. According to GB/T 3836.1-2021 and GB/T 3836.4-2021, it has passed the inspection and obtained the ccc certificate. It is suitable for installation and use in safe areas and can be used together with intrapexy safety equipment in Zone 0, Zone 1 and Zone 2 of explosive gas hazardous places.

Keywords: Isolator

• National Instrument Explosion-proof Safety Supervision and Inspection Station (CNEX) certification • Explosion-proof sign [Exia Ga] IIC According to GB3836.1, GB3836.4, GB3836.20 standard inspection, to obtain ccc certificate • Single channel, dual channel This series of varieties have one in and one out, one in and two out, two in and two out. • DC voltage, current, thermal resistance, thermocouple input • Analog output, loop-powered • The signal type and test range of some products can be programmed by the supporting PC software • Plug-in terminals for easy installation and maintenance • Standard 35mm DIN rail clip-on mount
  • Technical parameters
  • Structural outline drawing
  • Ordering Guide
  • Technical parameters

     

    Hazardous side
    Input signal type Various standard thermocouple signals (self-programming when ordering to determine or configure programming)
    Safety side
    Output signal type Analog output, RS-485 signal output, switch output
    Output load characteristics Current output: RL≤ 500 Ω, voltage output: RL≥ 250KΩ
    RS485 signal output Transmission delay ≤ 10μs, signal transmission rate ≤ 9.6kbps
    When the switching value is output

    Relay drive capacity: 125VAC/0.6A,30VDC/2A
    Relay response time:<5ms
    Transistor collector output: high level VCC(≤ 30V), low level ≤ 2.5V
    Transistor emitter output: high level VCC-2.5V, low level ≤ 0.5V

     

    General technical parameters 

     

    Power
    Power DC24V ±10%
    Power consumption Power consumption: ≤ 2.5W
    Other parameters
    Insulation strength
    (Between Inthenine Safety End/Non-Inthenine Safety End)
    1500Vrms (1 min, no spark)

    Working temperature
    Relative humidity

    -10~50 ℃ (no condensation, no icing)
    25%~85%RH
    save temperature -10~60 ℃ (no condensation, no icing)
    Installation method 35mm DIN rail mounting
    Mounting dimensions 17.5*111.4*121.2mm (width * height * depth)
    Transmission accuracy (20 ℃) 0.2%FS ± 1 word
    Weight About 130 grams
    Electromagnetic compatibility Comply with GB/T18268 industrial equipment application requirements (IEC 61326-1)
    Applicable field equipment Two-wire, three-wire transmitter, DC current source
  • Structural outline drawing

    结构外形图

    General Structure Exterior

     

    通用结构外型图

  •  

    1

     

    For example:

    Input signal: B type thermocouple, output signal: 4-20mA, one in and one out. Type selection: DST-60511-EX-00-0;

    Input signal: B type thermocouple, output signal: 4-20mA, one in and two out. Type selection: DST-60511-EX-00-0/0;

    Input signal: B type thermocouple, output signal: 4-20mA, two in and two out. Type selection: DST-60511-EX-00/00-0/0;

    Remarks:The temperature range can be indicated on the back of the model.