DST-601-EX voltage input isolated safety barrier
Classification:
Voltage analog input
DST-601X-EX-a/b-c/d type voltage input detection terminal isolation barrier, the voltage signal from the dangerous area is converted into voltage or current signal \RS485 signal \switch signal output to the safe area. The product requires independent power supply, input/output/power three isolation. A device that can be used to output voltage signals. According to GB/T 3836.1-2021 and GB/T 3836.4-2021, it has passed the inspection and obtained the ccc certificate. It is suitable for installation and use in safe areas and can be used together with intrapexy safety equipment in Zone 0, Zone 1 and Zone 2 of explosive gas hazardous places.
Keywords: Isolator
- Technical parameters
- Structural outline drawing
- Ordering Guide
-
Technical parameters
Hazardous side Input signal type 0~10mA,4~20mA,0~20mA,0 ~ 10mA square, 4 ~ 20mA square Input impedance ≤ 250Ω Safety side Output signal type Analog output, RS-485 signal output, switch output Output load characteristics Current output: RL≤ 500 Ω, voltage output: RL≥ 250KΩ RS485 signal output Transmission delay ≤ 10μs, signal transmission rate ≤ 9.6kbps When the switching value is output Relay drive capacity: 125VAC/0.6A,30VDC/2A
Relay response time:<20ms
Transistor collector output: high level VCC(≤ 30V), low level ≤ 2.5V
Transistor emitter output: high level VCC-2.5V, low level ≤ 0.5VGeneral technical parameters
Power Power DC24V ±10% Power consumption Power consumption: ≤ 2.5W Other parameters Insulation strength
(Between Inthenine Safety End/Non-Inthenine Safety End)1500Vrms (1 min, no spark) Working temperature
Relative humidity-10~50 ℃ (no condensation, no icing)
25%~85%RHsave temperature -10~60 ℃ (no condensation, no icing) Installation method 35mm DIN rail mounting Mounting dimensions 17.5*111.4*121.2mm (width * height * depth) Transmission accuracy (20 ℃) 0.2%FS ± 1 word Weight About 130 grams Electromagnetic compatibility Comply with GB/T18268 industrial equipment application requirements (IEC 61326-1) Applicable field equipment Two-wire, three-wire transmitter, DC current source -
Structural outline drawing

General Structure Exterior

-

When there are two outputs, there are three modes to choose from: A analog output analog output; B 485 output analog quantity; C switching value output switching value output;
For example:
Input signal: 0-5V, output signal: 0-5V, one in and one out. Type selection: DST-60211-EX-28-3;
Input signal: 0-5V, output signal: 0-5V, one in and two out. Type selection: DST-60212-EX-28-3/3;
Input signal: 0-5V, output signal: 0-5V, two in and two out. Selection: DST-60222-EX-28 -3/3;